Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials; [Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas]

MakaleYayıncıda açık erişimScopus SJRQ3
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/kostu/10333Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.15517/ijds.2023.56839Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
OpenAlex
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKopuz, Dilan
dc.contributor.authorSancak, Elifilgi
dc.contributor.authorTekçe, Neslihan
dc.date.accessioned2026-10-27T23:47:25.116821286Z
dc.date.available2026-10-27T23:47:25.116821286Z
dc.date.issued2024
dc.description.abstractThe purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.
dc.identifier.doi10.15517/ijds.2023.56839
dc.identifier.endpage85
dc.identifier.issn1659-1046
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85185675245
dc.identifier.startpage76
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/kostu/10333
dc.identifier.volume26
dc.language.isoen
dc.publisherUniversidad de Costa Rica
dc.relation.ispartofOdovtos - International Journal of Dental Sciences
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCAD/CAM
dc.subjectComposite
dc.subjectIvoclean
dc.subjectKatana Cleaner
dc.subjectShear bond strength
dc.subjectSurface decontamination
dc.titleEffect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials; [Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas]
dc.typeArticle
rdl.citation.openalex2
rdl.citation.scopus2
rdl.oa.statusgold
rdl.scopus.quartileQ3
rdl.sdgSDG03
rdl.source.indexSCOPUS