Impact of Adhesive Application Modes on Shear Bond Strength of Resin Composites to Biodentine

MakaleAçık Erişim
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Purpose: This in-vitro study aimed to evaluate the impact of the adhesive application mode on the shear bond strength of various resin composites to Biodentine. Materials and Methods: A total of 60 acrylic blocks, each with a central hole (2 mm x 5 mm), were made for the study (n = 60). The holes were filled with Biodentine (Septodont), and the samples were randomly divided into three groups based on the type of restorative material used: 1) conventional posterior composite, Estelite Posterior Quick (EP)(Tokuyama); 2) bulk-fill composite, Filtek Bulk Fill (FB) (3M ESPE); and 3) short fiber-reinforced composite, EverX Posterior (EX)(GC). Additionally, each group was subdivided into two categories depending on the adhesive application method: self-etch or total-etch. A universal adhesive (Single Bond Universal, 3M ESPE) was applied to the Biodentine specimens, and subsequently, the resin composites were applied and light-cured for 20 s. The shear bond strength was measured using a universal testing machine (AGS-1000D, Shimadzu) at a crosshead speed of 1 mm/min. The shear bond strength data (MPa) were analyzed using a two-way ANOVA and the Bonferroni test (p < 0.05). Results: For the self-etch application mode, a statistically significant difference was observed among the material groups (p = 0.005). Group EP exhibited higher shear bond strength compared to Group FB. There were also significant differences among the groups for the total-etch application mode (p = 0.009), with Group EP again showing the highest shear bond strength. However, when comparing the two etching modes within each material group, there were no significant differences in shear bond strength. Conclusions: The conventional posterior composite used significantly affects the strength of the shear bond to Biodentine. In contrast, the choice between self-etch and total-etch modes does not notably impact the bond strength.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/kostu/10905Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.52037/eads.2025.0007Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
3
TR Dizin
1
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDeger, Ceren
dc.contributor.authorOzduman, Zumrut Ceren
dc.contributor.authorDoğan, Miraç
dc.date.accessioned2026-10-27T23:48:57.631974809Z
dc.date.available2026-10-27T23:48:57.631974809Z
dc.date.issued2025
dc.description.abstractPurpose: This in-vitro study aimed to evaluate the impact of the adhesive application mode on the shear bond strength of various resin composites to Biodentine. Materials and Methods: A total of 60 acrylic blocks, each with a central hole (2 mm x 5 mm), were made for the study (n = 60). The holes were filled with Biodentine (Septodont), and the samples were randomly divided into three groups based on the type of restorative material used: 1) conventional posterior composite, Estelite Posterior Quick (EP)(Tokuyama); 2) bulk-fill composite, Filtek Bulk Fill (FB) (3M ESPE); and 3) short fiber-reinforced composite, EverX Posterior (EX)(GC). Additionally, each group was subdivided into two categories depending on the adhesive application method: self-etch or total-etch. A universal adhesive (Single Bond Universal, 3M ESPE) was applied to the Biodentine specimens, and subsequently, the resin composites were applied and light-cured for 20 s. The shear bond strength was measured using a universal testing machine (AGS-1000D, Shimadzu) at a crosshead speed of 1 mm/min. The shear bond strength data (MPa) were analyzed using a two-way ANOVA and the Bonferroni test (p < 0.05). Results: For the self-etch application mode, a statistically significant difference was observed among the material groups (p = 0.005). Group EP exhibited higher shear bond strength compared to Group FB. There were also significant differences among the groups for the total-etch application mode (p = 0.009), with Group EP again showing the highest shear bond strength. However, when comparing the two etching modes within each material group, there were no significant differences in shear bond strength. Conclusions: The conventional posterior composite used significantly affects the strength of the shear bond to Biodentine. In contrast, the choice between self-etch and total-etch modes does not notably impact the bond strength.
dc.identifier.doi10.52037/eads.2025.0007
dc.identifier.eissn2757-6744
dc.identifier.endpage49
dc.identifier.issue1
dc.identifier.startpage45
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/kostu/10905
dc.identifier.volume52
dc.language.isoen
dc.relation.ispartofEuropean annals of dental sciences (Online)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDiş Hekimliği
dc.subjectMalzeme Bilimleri, Biyomalzemeler
dc.titleImpact of Adhesive Application Modes on Shear Bond Strength of Resin Composites to Biodentine
dc.typeArticle
rdl.citation.openalex3
rdl.citation.trdizin1
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/4337958
rdl.sdgSDG03
rdl.source.indexTRDIZIN