Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials; [Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas]
Özet
The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.
Anahtar Kelimeler
- Scopus
- 2
- OpenAlex
- 2
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kopuz, Dilan | |
| dc.contributor.author | Sancak, Elifilgi | |
| dc.contributor.author | Tekçe, Neslihan | |
| dc.date.accessioned | 2026-10-27T23:47:25.116821286Z | |
| dc.date.available | 2026-10-27T23:47:25.116821286Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17 ± 3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces. | |
| dc.identifier.doi | 10.15517/ijds.2023.56839 | |
| dc.identifier.endpage | 85 | |
| dc.identifier.issn | 1659-1046 | |
| dc.identifier.issue | 1 | |
| dc.identifier.scopus | 2-s2.0-85185675245 | |
| dc.identifier.startpage | 76 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/kostu/10333 | |
| dc.identifier.volume | 26 | |
| dc.language.iso | en | |
| dc.publisher | Universidad de Costa Rica | |
| dc.relation.ispartof | Odovtos - International Journal of Dental Sciences | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | CAD/CAM | |
| dc.subject | Composite | |
| dc.subject | Ivoclean | |
| dc.subject | Katana Cleaner | |
| dc.subject | Shear bond strength | |
| dc.subject | Surface decontamination | |
| dc.title | Effect of Different Decontamination Agents on The Bond Strength of CAD/CAM Blocks and Repair Composite Materials; [Efecto de diferentes agentes descontaminantes sobre la resistencia de unión de bloques CAD/CAM y resinas compuestas] | |
| dc.type | Article | |
| rdl.citation.openalex | 2 | |
| rdl.citation.scopus | 2 | |
| rdl.oa.status | gold | |
| rdl.scopus.quartile | Q3 | |
| rdl.sdg | SDG03 | |
| rdl.source.index | SCOPUS |

