Optimizing Miniscrew Stability: A Finite Element Study of Titanium Screw Insertion Angles

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

This study aimed to evaluate how different insertion angles of titanium orthodontic miniscrews (30°, 45°, and 90°) influence stress distribution and displacement in surrounding alveolar bone using three-dimensional finite element analysis (FEA), with a focus on biomechanical outcomes at the titanium–bone interface. The 90° insertion angle generated the highest stress in cortical bone (58.2 MPa) but the lowest displacement (0.023 mm), while the 30° angle produced lower stress (36.4 MPa) but greater displacement (0.052 mm). The 45° angle represented a compromise, combining moderate stress (42.7 MPa) and displacement (0.035 mm). This simulation-based study was conducted between January and April 2025 at the Department of Orthodontics, Kocaeli Health and Technology University. A standardized 3D mandibular bone model (2 mm cortical and 13 mm cancellous layers) was constructed, and Ti-6Al-4V miniscrews (1.6 mm × 8 mm) were virtually inserted at 30°, 45°, and 90°. A horizontal orthodontic load of 2 N was applied, and von Mises stress and displacement values were calculated in ANSYS Workbench. Stress patterns were visualized using color-coded maps. The 90° insertion angle generated the highest von Mises stress in cortical bone (50.6 MPa), with a total maximum stress of 58.2 MPa, followed by 45° (42.7 MPa) and 30° (36.4 MPa) insertions (p < 0.001). Stress was predominantly concentrated at the cortical entry point, especially in the 90° model. In terms of displacement, the 90° group exhibited the lowest mean displacement (0.023 ± 0.002 mm), followed by 45° (0.035 ± 0.003 mm) and 30° (0.052 ± 0.004 mm), with statistically significant differences among all groups (p < 0.001). The 45° angle showed a balanced biomechanical profile, combining moderate stress and displacement values, as confirmed by post hoc analysis. From a biomimetics perspective, understanding how insertion angle affects bone response provides insights for designing bio-inspired anchorage systems. By simulating natural stress dissipation, this study demonstrates that insertion angle strongly modulates miniscrew performance. Vertical placement (90°) ensures rigidity but concentrates cortical stress, whereas oblique placement, particularly at 45°, offers a balanced compromise with adequate stability and reduced stress. These results emphasize that beyond material properties, surgical parameters such as insertion angle are critical for clinical success.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/kostu/10352Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/biomimetics10100650Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
4
WoS
4
OpenAlex
4
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkbulut, Yasin
dc.contributor.authorOzdemir, Serhat
dc.date.accessioned2026-10-27T23:47:26.948010427Z
dc.date.available2026-10-27T23:47:26.948010427Z
dc.date.issued2025
dc.description.abstractThis study aimed to evaluate how different insertion angles of titanium orthodontic miniscrews (30°, 45°, and 90°) influence stress distribution and displacement in surrounding alveolar bone using three-dimensional finite element analysis (FEA), with a focus on biomechanical outcomes at the titanium–bone interface. The 90° insertion angle generated the highest stress in cortical bone (58.2 MPa) but the lowest displacement (0.023 mm), while the 30° angle produced lower stress (36.4 MPa) but greater displacement (0.052 mm). The 45° angle represented a compromise, combining moderate stress (42.7 MPa) and displacement (0.035 mm). This simulation-based study was conducted between January and April 2025 at the Department of Orthodontics, Kocaeli Health and Technology University. A standardized 3D mandibular bone model (2 mm cortical and 13 mm cancellous layers) was constructed, and Ti-6Al-4V miniscrews (1.6 mm × 8 mm) were virtually inserted at 30°, 45°, and 90°. A horizontal orthodontic load of 2 N was applied, and von Mises stress and displacement values were calculated in ANSYS Workbench. Stress patterns were visualized using color-coded maps. The 90° insertion angle generated the highest von Mises stress in cortical bone (50.6 MPa), with a total maximum stress of 58.2 MPa, followed by 45° (42.7 MPa) and 30° (36.4 MPa) insertions (p < 0.001). Stress was predominantly concentrated at the cortical entry point, especially in the 90° model. In terms of displacement, the 90° group exhibited the lowest mean displacement (0.023 ± 0.002 mm), followed by 45° (0.035 ± 0.003 mm) and 30° (0.052 ± 0.004 mm), with statistically significant differences among all groups (p < 0.001). The 45° angle showed a balanced biomechanical profile, combining moderate stress and displacement values, as confirmed by post hoc analysis. From a biomimetics perspective, understanding how insertion angle affects bone response provides insights for designing bio-inspired anchorage systems. By simulating natural stress dissipation, this study demonstrates that insertion angle strongly modulates miniscrew performance. Vertical placement (90°) ensures rigidity but concentrates cortical stress, whereas oblique placement, particularly at 45°, offers a balanced compromise with adequate stability and reduced stress. These results emphasize that beyond material properties, surgical parameters such as insertion angle are critical for clinical success.
dc.identifier.articlenumber650
dc.identifier.doi10.3390/biomimetics10100650
dc.identifier.eissn2313-7673
dc.identifier.issn2313-7673
dc.identifier.issue10
dc.identifier.pmcidPMC12561844
dc.identifier.pmid41149180
dc.identifier.scopus2-s2.0-105020018430
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/kostu/10352
dc.identifier.volume10
dc.identifier.wosWOS:001603800400001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofBiomimetics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectbiomechanics
dc.subjectcortical bone stress
dc.subjectfinite element analysis
dc.subjectinsertion angle
dc.subjectorthodontic miniscrew
dc.subjectprimary stability
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationMaterials Science, Biomaterials
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.other3D modeling
dc.subject.otherAluminum alloys
dc.subject.otherBone
dc.subject.otherColor
dc.subject.otherDental orthoses
dc.subject.otherDentistry
dc.subject.otherStress concentration
dc.subject.otherTernary alloys
dc.subject.otherThree dimensional computer graphics
dc.subject.otherTitanium
dc.subject.otherTitanium alloys
dc.subject.otherVanadium alloys
dc.subject.otherCortical bone
dc.subject.otherCortical bone stress
dc.subject.otherFinite element analyse
dc.subject.otherInsertion angles
dc.subject.otherMiniscrews
dc.subject.otherOrthodontic miniscrew
dc.subject.otherPrimary stabilities
dc.subject.otherStress and displacements
dc.subject.otherTitania
dc.subject.otherVonMises stress
dc.subject.otherBiomechanics
dc.titleOptimizing Miniscrew Stability: A Finite Element Study of Titanium Screw Insertion Angles
dc.typeArticle
rdl.citation.openalex4
rdl.citation.scopus4
rdl.citation.wos4
rdl.departmentDepartment of Orthodontics, Kocaeli Health and Technology University, 41275 Kocaeli, Turkey
rdl.departmentDepartment of Orthodontics, Private Clinics, 63320 Sanliurfa, Turkey
rdl.oa.statusgold
rdl.oa.statusgreen
rdl.oa.urlhttps://www.mdpi.com/2313-7673/10/10/650/pdf?version=1759285719
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)