Myval Transcatheter Heart Valve: The Future of Transcatheter Valve Replacement and Significance in Current Timeline
Özet
The Myval is a balloon-expandable transcatheter heart valve (THV) developed by Meril Life Sciences Pvt. Ltd. (Vapi, Gujarat, India) that has an innovative operator-friendly design that aids in improving deliverability and features precise deployment. Various clinical studies demonstrate its effectiveness and safety, making it a promising choice in valvular interventions. Myval has been successfully utilized as a transcatheter aortic valve implantation (TAVI) device in cases with conduction disturbances, bicuspid aortic valve anatomy, non-calcified aortic regurgitation, dysfunctional stenosed right ventricular outflow tract (RVOT) conduits, pulmonary valve replacement, mitral valve replacement, and valve-in-valve and valve-in-ring implantation procedures. Myval’s diverse sizes are also of key importance in complex cases of large annuli and complex anatomy. Further long-term studies are needed to consolidate these results. Its introduction signifies a significant advancement in cardiology, aiming to enhance patient outcomes and quality of life. In the present review, we provide an update on new-generation Myval THV series and review the available clinical data published to date with an emphasis on diverse use in specific clinical scenarios.
Anahtar Kelimeler
- Scopus
- 13
- WoS
- 13
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kilic, Teoman | |
| dc.contributor.author | Coskun, Senol | |
| dc.contributor.author | Mirzamidinov, Didar | |
| dc.contributor.author | Yilmaz, Irem | |
| dc.contributor.author | Yavuz, Sadan | |
| dc.contributor.author | Sahin, Tayfun | |
| dc.date.accessioned | 2026-10-27T23:47:44.576018170Z | |
| dc.date.available | 2026-10-27T23:47:44.576018170Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | The Myval is a balloon-expandable transcatheter heart valve (THV) developed by Meril Life Sciences Pvt. Ltd. (Vapi, Gujarat, India) that has an innovative operator-friendly design that aids in improving deliverability and features precise deployment. Various clinical studies demonstrate its effectiveness and safety, making it a promising choice in valvular interventions. Myval has been successfully utilized as a transcatheter aortic valve implantation (TAVI) device in cases with conduction disturbances, bicuspid aortic valve anatomy, non-calcified aortic regurgitation, dysfunctional stenosed right ventricular outflow tract (RVOT) conduits, pulmonary valve replacement, mitral valve replacement, and valve-in-valve and valve-in-ring implantation procedures. Myval’s diverse sizes are also of key importance in complex cases of large annuli and complex anatomy. Further long-term studies are needed to consolidate these results. Its introduction signifies a significant advancement in cardiology, aiming to enhance patient outcomes and quality of life. In the present review, we provide an update on new-generation Myval THV series and review the available clinical data published to date with an emphasis on diverse use in specific clinical scenarios. | |
| dc.identifier.articlenumber | 6857 | |
| dc.identifier.doi | 10.3390/jcm13226857 | |
| dc.identifier.eissn | 2077-0383 | |
| dc.identifier.issn | 2077-0383 | |
| dc.identifier.issue | 22 | |
| dc.identifier.pmcid | PMC11594825 | |
| dc.identifier.pmid | 39598000 | |
| dc.identifier.scopus | 2-s2.0-85210158083 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/kostu/10692 | |
| dc.identifier.volume | 13 | |
| dc.identifier.wos | WOS:001365392200001 | |
| dc.language.iso | en | |
| dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | |
| dc.relation.ispartof | Journal of Clinical Medicine | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Myval | |
| dc.subject | safety | |
| dc.subject | transcatheter aortic valve implantation | |
| dc.subject | transcatheter heart valve | |
| dc.subject | valve-in-valve implantation | |
| dc.subject.classification | Medicine, General & Internal | |
| dc.subject.classification | General & Internal Medicine | |
| dc.subject.other | adverse device effect | |
| dc.subject.other | aortic regurgitation | |
| dc.subject.other | bicuspid aortic valve | |
| dc.subject.other | clinical article | |
| dc.subject.other | complication | |
| dc.subject.other | heart muscle conduction disturbance | |
| dc.subject.other | heart right ventricle outflow tract | |
| dc.subject.other | heart valve | |
| dc.subject.other | heart valve replacement | |
| dc.subject.other | human | |
| dc.subject.other | mitral valve replacement | |
| dc.subject.other | nonhuman | |
| dc.subject.other | pulmonary valve replacement | |
| dc.subject.other | review | |
| dc.subject.other | surgery | |
| dc.subject.other | transcatheter aortic valve implantation | |
| dc.subject.other | treatment outcome | |
| dc.title | Myval Transcatheter Heart Valve: The Future of Transcatheter Valve Replacement and Significance in Current Timeline | |
| dc.type | Review Article | |
| rdl.citation.scopus | 13 | |
| rdl.citation.wos | 13 | |
| rdl.department | Structural Heart Interventions Unit, Department of Cardiology, Kocaeli University School of Medicine, Kocaeli 41380, Turkey | |
| rdl.department | Faculty of Health Sciences, Kocaeli Health and Technology University, Kocaeli 41275, Turkey | |
| rdl.department | Department of Cardiovascular Surgery, Kocaeli University School of Medicine, Kocaeli 41380, Turkey | |
| rdl.oa.status | gold | |
| rdl.oa.status | green | |
| rdl.oa.url | https://www.mdpi.com/2077-0383/13/22/6857/pdf?version=1731580531 | |
| rdl.scopus.quartile | Q1 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |