Optimizing Miniscrew Stability: A Finite Element Study of Titanium Screw Insertion Angles
Özet
This study aimed to evaluate how different insertion angles of titanium orthodontic miniscrews (30°, 45°, and 90°) influence stress distribution and displacement in surrounding alveolar bone using three-dimensional finite element analysis (FEA), with a focus on biomechanical outcomes at the titanium–bone interface. The 90° insertion angle generated the highest stress in cortical bone (58.2 MPa) but the lowest displacement (0.023 mm), while the 30° angle produced lower stress (36.4 MPa) but greater displacement (0.052 mm). The 45° angle represented a compromise, combining moderate stress (42.7 MPa) and displacement (0.035 mm). This simulation-based study was conducted between January and April 2025 at the Department of Orthodontics, Kocaeli Health and Technology University. A standardized 3D mandibular bone model (2 mm cortical and 13 mm cancellous layers) was constructed, and Ti-6Al-4V miniscrews (1.6 mm × 8 mm) were virtually inserted at 30°, 45°, and 90°. A horizontal orthodontic load of 2 N was applied, and von Mises stress and displacement values were calculated in ANSYS Workbench. Stress patterns were visualized using color-coded maps. The 90° insertion angle generated the highest von Mises stress in cortical bone (50.6 MPa), with a total maximum stress of 58.2 MPa, followed by 45° (42.7 MPa) and 30° (36.4 MPa) insertions (p < 0.001). Stress was predominantly concentrated at the cortical entry point, especially in the 90° model. In terms of displacement, the 90° group exhibited the lowest mean displacement (0.023 ± 0.002 mm), followed by 45° (0.035 ± 0.003 mm) and 30° (0.052 ± 0.004 mm), with statistically significant differences among all groups (p < 0.001). The 45° angle showed a balanced biomechanical profile, combining moderate stress and displacement values, as confirmed by post hoc analysis. From a biomimetics perspective, understanding how insertion angle affects bone response provides insights for designing bio-inspired anchorage systems. By simulating natural stress dissipation, this study demonstrates that insertion angle strongly modulates miniscrew performance. Vertical placement (90°) ensures rigidity but concentrates cortical stress, whereas oblique placement, particularly at 45°, offers a balanced compromise with adequate stability and reduced stress. These results emphasize that beyond material properties, surgical parameters such as insertion angle are critical for clinical success.
Anahtar Kelimeler
- Scopus
- 4
- WoS
- 4
- OpenAlex
- 4
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Akbulut, Yasin | |
| dc.contributor.author | Ozdemir, Serhat | |
| dc.date.accessioned | 2026-10-27T23:47:26.948010427Z | |
| dc.date.available | 2026-10-27T23:47:26.948010427Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | This study aimed to evaluate how different insertion angles of titanium orthodontic miniscrews (30°, 45°, and 90°) influence stress distribution and displacement in surrounding alveolar bone using three-dimensional finite element analysis (FEA), with a focus on biomechanical outcomes at the titanium–bone interface. The 90° insertion angle generated the highest stress in cortical bone (58.2 MPa) but the lowest displacement (0.023 mm), while the 30° angle produced lower stress (36.4 MPa) but greater displacement (0.052 mm). The 45° angle represented a compromise, combining moderate stress (42.7 MPa) and displacement (0.035 mm). This simulation-based study was conducted between January and April 2025 at the Department of Orthodontics, Kocaeli Health and Technology University. A standardized 3D mandibular bone model (2 mm cortical and 13 mm cancellous layers) was constructed, and Ti-6Al-4V miniscrews (1.6 mm × 8 mm) were virtually inserted at 30°, 45°, and 90°. A horizontal orthodontic load of 2 N was applied, and von Mises stress and displacement values were calculated in ANSYS Workbench. Stress patterns were visualized using color-coded maps. The 90° insertion angle generated the highest von Mises stress in cortical bone (50.6 MPa), with a total maximum stress of 58.2 MPa, followed by 45° (42.7 MPa) and 30° (36.4 MPa) insertions (p < 0.001). Stress was predominantly concentrated at the cortical entry point, especially in the 90° model. In terms of displacement, the 90° group exhibited the lowest mean displacement (0.023 ± 0.002 mm), followed by 45° (0.035 ± 0.003 mm) and 30° (0.052 ± 0.004 mm), with statistically significant differences among all groups (p < 0.001). The 45° angle showed a balanced biomechanical profile, combining moderate stress and displacement values, as confirmed by post hoc analysis. From a biomimetics perspective, understanding how insertion angle affects bone response provides insights for designing bio-inspired anchorage systems. By simulating natural stress dissipation, this study demonstrates that insertion angle strongly modulates miniscrew performance. Vertical placement (90°) ensures rigidity but concentrates cortical stress, whereas oblique placement, particularly at 45°, offers a balanced compromise with adequate stability and reduced stress. These results emphasize that beyond material properties, surgical parameters such as insertion angle are critical for clinical success. | |
| dc.identifier.articlenumber | 650 | |
| dc.identifier.doi | 10.3390/biomimetics10100650 | |
| dc.identifier.eissn | 2313-7673 | |
| dc.identifier.issn | 2313-7673 | |
| dc.identifier.issue | 10 | |
| dc.identifier.pmcid | PMC12561844 | |
| dc.identifier.pmid | 41149180 | |
| dc.identifier.scopus | 2-s2.0-105020018430 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/kostu/10352 | |
| dc.identifier.volume | 10 | |
| dc.identifier.wos | WOS:001603800400001 | |
| dc.language.iso | en | |
| dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | |
| dc.relation.ispartof | Biomimetics | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | biomechanics | |
| dc.subject | cortical bone stress | |
| dc.subject | finite element analysis | |
| dc.subject | insertion angle | |
| dc.subject | orthodontic miniscrew | |
| dc.subject | primary stability | |
| dc.subject.classification | Engineering, Multidisciplinary | |
| dc.subject.classification | Materials Science, Biomaterials | |
| dc.subject.classification | Engineering | |
| dc.subject.classification | Materials Science | |
| dc.subject.other | 3D modeling | |
| dc.subject.other | Aluminum alloys | |
| dc.subject.other | Bone | |
| dc.subject.other | Color | |
| dc.subject.other | Dental orthoses | |
| dc.subject.other | Dentistry | |
| dc.subject.other | Stress concentration | |
| dc.subject.other | Ternary alloys | |
| dc.subject.other | Three dimensional computer graphics | |
| dc.subject.other | Titanium | |
| dc.subject.other | Titanium alloys | |
| dc.subject.other | Vanadium alloys | |
| dc.subject.other | Cortical bone | |
| dc.subject.other | Cortical bone stress | |
| dc.subject.other | Finite element analyse | |
| dc.subject.other | Insertion angles | |
| dc.subject.other | Miniscrews | |
| dc.subject.other | Orthodontic miniscrew | |
| dc.subject.other | Primary stabilities | |
| dc.subject.other | Stress and displacements | |
| dc.subject.other | Titania | |
| dc.subject.other | VonMises stress | |
| dc.subject.other | Biomechanics | |
| dc.title | Optimizing Miniscrew Stability: A Finite Element Study of Titanium Screw Insertion Angles | |
| dc.type | Article | |
| rdl.citation.openalex | 4 | |
| rdl.citation.scopus | 4 | |
| rdl.citation.wos | 4 | |
| rdl.department | Department of Orthodontics, Kocaeli Health and Technology University, 41275 Kocaeli, Turkey | |
| rdl.department | Department of Orthodontics, Private Clinics, 63320 Sanliurfa, Turkey | |
| rdl.oa.status | gold | |
| rdl.oa.status | green | |
| rdl.oa.url | https://www.mdpi.com/2313-7673/10/10/650/pdf?version=1759285719 | |
| rdl.scopus.quartile | Q2 | |
| rdl.sdg | SDG03 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |

