In Vitro Evaluation of Color Changes in CAD/CAM Materials Due to Long-Term Water Aging; [Evaluación In Vitro de los cambios de color en materiales CAD/CAM debido al envejecimiento prolongado por exposición al agua]

MakaleAçık ErişimScopus SJRQ3

Özet

The aim of this study is to examine the discoloration in CAD/CAM materials used in dentistry after 4-years of contact with water, which is the environment to which they are most exposed in the oral cavity. Three different A2-colored resin-based CAD/CAM blocks (Cerasmart, Coltene Brilliant Crios and Shofu Block HC) were used in our study. A total of 180 specimens, 60 of each CAD/CAM material, were prepared with a thickness of 2-mm. Then, each material was divided into three different groups based on the polishing systems (Coltene Diatech, Sof-Lex Diamond, Identoflex Diamond Ceramic) applied in accordance with the recommendations of the manufacturing companies (n:20). The discoloration of the materials on a white background and under natural light sources at the beginning and after being stored in distilled water for 4-years were measured with the VITA EasyshadeV spectrophotometer. All the obtained data were examined using the Kolmogorov Smirnov and Shapiro Wilk Normality Test values. After the water aging process, no statistically significant difference was found between the Cerasmart (p=1.51; p>0.05) and Shofu (p=0.95; p>0.05) CAD/CAM material groups using three different polishing systems. A statistically significant difference was found between all polishing system groups of Coltene CAD/ CAM materials (p=0.00). All CAD/CAM materials showed color changes above the ΔE00≤0.8 perceptibility threshold after being aged in distilled water for 4 years. Cerasmart CAD/CAM blocks (Coltene ΔE00=1.33, Sof-lex ΔE00=1.43, Identoflex ΔE00=1.69) showed color changes below the ΔE00≤1.8 acceptability threshold in all groups where different polishing systems were applied, while Coltene (Coltene ΔE00=3.7, Sof-lex ΔE00=3.81, Identoflex ΔE00=4.69) and Shofu (Coltene ΔE00=2.33, Sof-lex ΔE00=1.74, Identoflex ΔE00=1.91) blocks showed color changes above the acceptable threshold value.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/kostu/10393Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.15517/kyea6q06Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSancak, Elif İ.
dc.contributor.authorBilgin, Selen Bozkaya
dc.contributor.authorTekçe, Neslihan
dc.contributor.authorSarıhan, Kübra Kavram
dc.date.accessioned2026-10-27T23:47:28.871954670Z
dc.date.available2026-10-27T23:47:28.871954670Z
dc.date.issued2026
dc.description.abstractThe aim of this study is to examine the discoloration in CAD/CAM materials used in dentistry after 4-years of contact with water, which is the environment to which they are most exposed in the oral cavity. Three different A2-colored resin-based CAD/CAM blocks (Cerasmart, Coltene Brilliant Crios and Shofu Block HC) were used in our study. A total of 180 specimens, 60 of each CAD/CAM material, were prepared with a thickness of 2-mm. Then, each material was divided into three different groups based on the polishing systems (Coltene Diatech, Sof-Lex Diamond, Identoflex Diamond Ceramic) applied in accordance with the recommendations of the manufacturing companies (n:20). The discoloration of the materials on a white background and under natural light sources at the beginning and after being stored in distilled water for 4-years were measured with the VITA EasyshadeV spectrophotometer. All the obtained data were examined using the Kolmogorov Smirnov and Shapiro Wilk Normality Test values. After the water aging process, no statistically significant difference was found between the Cerasmart (p=1.51; p>0.05) and Shofu (p=0.95; p>0.05) CAD/CAM material groups using three different polishing systems. A statistically significant difference was found between all polishing system groups of Coltene CAD/ CAM materials (p=0.00). All CAD/CAM materials showed color changes above the ΔE00≤0.8 perceptibility threshold after being aged in distilled water for 4 years. Cerasmart CAD/CAM blocks (Coltene ΔE00=1.33, Sof-lex ΔE00=1.43, Identoflex ΔE00=1.69) showed color changes below the ΔE00≤1.8 acceptability threshold in all groups where different polishing systems were applied, while Coltene (Coltene ΔE00=3.7, Sof-lex ΔE00=3.81, Identoflex ΔE00=4.69) and Shofu (Coltene ΔE00=2.33, Sof-lex ΔE00=1.74, Identoflex ΔE00=1.91) blocks showed color changes above the acceptable threshold value.
dc.description.sponsorshipKocaeli Health and Technology University Scientific Research Projects Coordinators [2023/23]
dc.identifier.doi10.15517/kyea6q06
dc.identifier.eissn2215-3411
dc.identifier.endpage230
dc.identifier.issn1659-1046
dc.identifier.issue2
dc.identifier.scopus2-s2.0-105040066243
dc.identifier.startpage220
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/kostu/10393
dc.identifier.volume28
dc.identifier.wosWOS:001779915900019
dc.language.isoen
dc.publisherUniversidad de Costa Rica
dc.relation.ispartofOdovtos - International Journal of Dental Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject, Spectrophotometry
dc.subjectCAD/CAM block
dc.subjectColor stability
dc.subjectDental materials
dc.subjectPolishing systems
dc.subjectWater aging
dc.subject.classificationDentistry, Oral Surgery & Medicine
dc.subject.otherRESIN-COMPOSITE BLOCKS
dc.subject.otherSURFACE-ROUGHNESS
dc.subject.otherBOND STRENGTH
dc.subject.otherSTABILITY
dc.subject.otherIMMERSION
dc.subject.otherCERAMICS
dc.subject.otherSYSTEMS
dc.titleIn Vitro Evaluation of Color Changes in CAD/CAM Materials Due to Long-Term Water Aging; [Evaluación In Vitro de los cambios de color en materiales CAD/CAM debido al envejecimiento prolongado por exposición al agua]
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statusgold
rdl.oa.urlhttps://revistas.ucr.ac.cr/index.php/rOdontos/article/download/2462/5291
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)